NaOH 50% -- Technical Specifications, Applications & Price List (CAS 1310-73-2)

Key Technical Summary: NaOH 50% (CAS 1310-73-2, d=1.52) — COA, 6 industry applications, dosage, 2026 pricing. Tanker delivery. Call 0979 891 929.
Table of contents
NaOH 50% (CAS 1310-73-2) is a commercial concentrated sodium hydroxide solution, specific gravity 1.52 g/mL, NaOH content 50% nominal (actual value per batch COA). 6 industry applications: wastewater treatment, paper production, textile dyeing, soap manufacturing, food processing, oil & gas. Loc Thien supplies by tanker truck 5–30 tons, IBC 1000L, COA per batch — Tax ID 0313650856 — Hotline 0979 891 929.
What Is NaOH 50%? — COA Parameters and Basic Properties
NaOH 50% (sodium hydroxide 50%, liquid caustic soda 50%) is a strong alkali solution produced by ion-exchange membrane electrolysis technology. Below are typical COA parameters from Hoa Chat Loc Thien.
Typical COA — NaOH 50%
| Parameter | Value | Test Method |
|---|---|---|
| NaOH concentration | 50% nominal (actual value per batch COA) | HCl titration |
| Specific gravity @20°C | 1.52 g/mL | Hydrometer / ASTM D891 |
| NaCl content | Per batch COA | AgNO₃ titration |
| Na₂CO₃ content | Per batch COA | HCl titration |
| Fe content | Per batch COA | ICP-OES |
| Freezing point | ~ +12°C | — |
| pH (1% solution) | ~ 13.5 | pH meter |
| CAS | 1310-73-2 | — |
| Formula | NaOH | — |
| UN number | 1824 | — |
| Hazard class | Class 8 (corrosive) | — |
NaOH 50% vs. 32% vs. 45%
All three concentrations are liquid NaOH solutions. The key differences lie in active ingredient content and freezing point.
| Parameter | NaOH 32% | NaOH 45% | NaOH 50% |
|---|---|---|---|
| Specific gravity @20°C | ~1.348 g/mL | ~1.478 g/mL | 1.52 g/mL |
| Freezing point | ~ +5°C | ~ +6–7°C | ~ +12°C |
| kg NaOH 100%/1,000L | 431 kg | 665 kg | 760 kg |
| Transport cost/kg NaOH 100% | Highest | Medium | Lowest |
NaOH 50% offers the lowest transport cost per kg of active ingredient — approximately 36% less solution mass (~43% less volume) than 32%. The freezing point of +12°C requires heat tracing and insulation during winter.
6 Main Industrial Applications
Wastewater Treatment — pH Neutralization and Heavy Metal Precipitation
NaOH 50% is used to neutralize acidic waste streams (pH < 6) to 6.5–8.5 before discharge. Reference dosage: 0.1–0.5 kg NaOH 50%/m³ of wastewater depending on influent acid load.
For heavy metal treatment, NaOH 50% precipitates metal ions as hydroxides: Cu²⁺ + 2OH⁻ → Cu(OH)₂↓; Zn²⁺ + 2OH⁻ → Zn(OH)₂↓; Cr³⁺ + 3OH⁻ → Cr(OH)₃↓. Removal efficiency exceeds 99% when maintaining pH 8.5–9.5.
Paper Production (Kraft Pulping) — Lignin Removal, Pulp Bleaching
In the Kraft process, NaOH 50% together with Na₂S forms white liquor to break lignin-cellulose bonds. Typical consumption: 150–200 kg NaOH 100%/ton of pulp. NaOH 50% is preferred because higher concentration reduces water volume entering the digester, increasing digester productivity.
Textile Dyeing — Mercerizing, Bleaching, pH Adjustment
NaOH 50% is used in the mercerizing process — treating cotton fabric with concentrated alkali (20–28°Be) to increase luster, color fastness, and dye uptake. Dosage: 30–80 kg NaOH/ton fabric depending on mercerizing machine type. Requires high-purity NaOH with low NaCl and Na₂CO₃. A low NaCl level, as stated on the batch COA, helps avoid undesirable white spots on fabric surfaces.
Soap and Detergent Production — Saponification
Reaction: triglyceride + NaOH → glycerol + fatty acid salt (soap). Dosage: 130–140 kg NaOH 100%/ton of oil/fat depending on SAP value (≈ 260–280 kg NaOH 50%). NaOH 50% is preferred in industrial soap production due to its smaller volume compared to 32%, reducing delivery frequency and storage tank capacity.
Food Processing — Fruit Peeling, CIP, Sugar Production
In CIP (Clean-in-Place) processes, NaOH 50% is diluted to 0.5–2%, circulated at 60–80°C for 10–30 minutes to clean tanks and pipes. AISI 304/316 stainless steel is fully compatible at this concentration. Other applications: fruit peeling (soaking in 1–3% NaOH), ion exchange resin regeneration in sugar production.
Oil & Gas Industry — Acid Neutralization, Sulfur Purification
NaOH 50% neutralizes H₂S and acidic compounds in natural gas and crude oil. The Claus sulfur treatment process requires NaOH to absorb and neutralize residual H₂S.
Dilution and Dosage Calculation Guide
Basic formula: m₁ × C₁ = m₂ × C₂, where m₁ = mass of NaOH 50% needed (kg), C₁ = NaOH 50% concentration (50%), m₂ = mass of solution to prepare (kg), C₂ = desired concentration (%).
Example: CIP process needs 500 kg of 5% NaOH solution → m₁ = 500 × 5 ÷ 50 = 50 kg NaOH 50%.
Safe dilution: Always add NaOH slowly to water (never reverse). Diluting NaOH 50% generates significant heat — requires continuous stirring and slow addition to prevent overheating (thermal shock can crack plastic tanks).
Operating Considerations
Freezing Point +12°C — Risks and Solutions
NaOH 50% begins to crystallize at approximately +12°C — clearly higher than 32% (about +5°C; a 31–33% batch can start anywhere from about 2 to 8°C) and 45% (about +6–7°C). Crystals may not appear right away even below the crystallization point, and outdoor pipes, valves and pump heads crystallize first. Reference figures follow the NaOH–H₂O phase diagram and technical literature from caustic soda producers; the actual crystallization point depends on each batch’s concentration per its COA/TDS. In northern Vietnam, winter temperatures can drop below 10°C. Solution: heat tracing with heating tape or steam, insulation of storage tanks and piping with fiberglass or polyurethane. When NaOH 50% has solidified, never heat directly with flame or immersion heaters — use indirect heating with steam jacket or hot water.
Compatible Storage Tank Materials
| Material | Recommendation |
|---|---|
| Stainless steel 304/316 | ✅ Fully compatible |
| Carbon steel | ✅ Suitable (temperature ≤ 50°C) |
| HDPE, PP, PVC | ✅ Suitable |
| Aluminum | ❌ Rapid corrosion |
| Zinc / Galvanized | ❌ Not suitable |
| Copper / Copper alloys | ❌ Not suitable |
Case Study — Cost Savings from Switching from NaOH 32% to 50%
A paper mill at Nhon Trach Industrial Park consuming 80 tons NaOH 100%/month had used NaOH 32% for 10 years. The mill switched to NaOH 50% to reduce logistics costs and free up warehouse space.
Actual data:
| Item | NaOH 32% | NaOH 50% |
|---|---|---|
| Monthly solution volume | 250 tons | 160 tons |
| Tanker truck trips/month | 12–13 | 8 |
| Required tank capacity | 50 m³ | 30 m³ |
Results after 6 months: Transport cost reduced 36%/month, tank reduced from 50m³ to 30m³ freeing 20m³ for other chemicals, reduced 1 staff for receiving and pumping, no change in pulp quality.
ROI and Payback Period
Investment: new tank + heat tracing + valve and pump modifications — equivalent to roughly 4 months of logistics savings (36% lower per month), so the payback period is ~4 months.
Latest 2026 Pricing
Why there is no fixed price list
NaOH 50% is supplied in bulk lots to factories, industrial parks and wastewater plants. The actual unit price depends on volume, delivery region, packaging and contract terms, and source prices and exchange rates also change over time. A single published number would not reflect your real cost — so Loc Thien issues a written quotation for each request, with a stated validity period.
5 factors that determine the NaOH 50% unit price
| Factor | Effect on unit price | What you need to provide |
|---|---|---|
| Volume per delivery / month | Larger, regular offtake → lower price per kg | Tons per delivery, frequency |
| Delivery region | Close to a warehouse → lower freight; long distance → higher freight | Plant address / industrial park |
| Packaging | 5–30-ton tanker has the lowest cost per kg; 30 kg cans, 250 kg drums and 1000L IBCs add container and filling costs | Preferred packaging |
| Concentration & specifications | NaCl, Fe or Na₂CO₃ limits tighter than the typical COA affect sourcing | Concentration, mandatory COA parameters |
| Contract type | Monthly/quarterly/annual framework contracts get more stable pricing than spot orders | Spot or recurring, payment terms |
What a Loc Thien NaOH 50% quotation includes
- Unit price per kg or per ton of solution, with the concentration stated
- Price with or without VAT — full VAT invoice (Tax ID 0313650856)
- Freight to your plant, or ex-warehouse price
- Payment terms and quotation validity
- Estimated delivery: HCMC inner city 4 hours; Southern and Mekong industrial parks 24–48 hours; North and Central 2–3 days
- Batch COA and MSDS
Real Cost Comparison Between Suppliers
Comparing price per kg of solution is not enough — convert to cost per kg of NaOH 100%.
Formula: Cost/kg NaOH 100% = Price/kg solution ÷ Concentration (as a decimal)
Example: you receive quotes of P₃₂ for 32% caustic and P₅₀ for 50% caustic (VND/kg solution). Compare P₃₂ ÷ 0.32 with P₅₀ ÷ 0.50 — 50% is cheaper per kg of active NaOH whenever P₅₀ < 1.5625 × P₃₂. Freight is charged on solution weight, which tips the balance further toward 50% (about 36% less mass to haul).
Get a quote within 15 minutes: send concentration, volume, delivery location, packaging and COA requirements via 0979 891 929, [email protected] or the quote request form.
Technical Support & B2B Procurement Hotline
Loc Thien Chemical specializes in direct manufacturing of FeCl₂ / FeCl₃ and direct industrial supply of basic chemicals (NaOH, HCl, H₂SO₄, PAC, NaOCl, H₂O₂, FeSO₄) with direct B2B pricing and dedicated 5–30-ton tanker delivery across Vietnam.
- Hotline / Zalo: +84 979 891 929
- Official Email: [email protected]
- Direct Manufacturer: Ferrous Chloride (FeCl₂ 30%) & Ferric Chloride (FeCl₃ 38–40%)
- Primary Supplier: NaOH 32%/45%/50%/99%, HCl 32%, H₂SO₄ 98%, PAC 30–31%, NaOCl 10–12%, H₂O₂ 35%/50%
- Compliance & Quality: FeCl₂ ZDHC MRSL v3.1 test report (Smart testing, 5 substance groups, TUV Rheinland Vietnam), ISO 9001:2015, Quatest 3, Full COA & GHS SDS
Frequently Asked Questions
Does NaOH 50% corrode stainless steel?
NaOH 50% does not corrode AISI 304/316 stainless steel at temperatures below 80°C. This material is recommended for storage tanks. Do not use aluminum, zinc, copper, or galvanized tanks.
At what temperature does NaOH 50% solidify?
NaOH 50% begins solidifying at approximately +12°C. Below 12°C, NaOH·nH₂O crystals form, clogging valves and pipes. Heat tracing and insulation are required in winter.
Where can I buy large quantities of NaOH 50%?
Hoa Chat Loc Thien supplies NaOH 50% in 5–30 ton tank trucks and 1000L IBCs nationwide — 6 warehouses, a fleet of tank trucks. Delivery within 4 hours in inner HCMC. Hotline 0979 891 929.
What is the difference between NaOH 50% and NaOH 32%?
NaOH 50% has higher specific gravity (1.52 vs 1.348), higher freezing point (about +12°C vs about +5°C), but transport cost per kg NaOH 100% is ~36% lower. NaOH 50% suits large-scale plants with heat tracing; NaOH 32% suits small plants in hot climates.
How to check NaOH 50% quality at the warehouse?
Measure specific gravity with hydrometer at 20°C — NaOH 50% has SG 1.52 g/mL. Titrate with 1N HCl using phenolphthalein indicator for precise NaOH content determination.
Is a special permit needed to transport NaOH 50%?
NaOH 50% is classified as UN 1824, Class 8 — tank trucks must be registered for dangerous goods. Loc Thien has a fleet of dedicated tank trucks with full dangerous goods registration and certified drivers.
Industrial Field Operation & Batch Quality Verification
1. Incoming Batch COA Verification & Regulatory Compliance (Law on Chemicals 69/2025/QH15)
When operating industrial water treatment, surface finishing, or textile dyeing lines in Vietnam, engineering teams must verify every chemical delivery against its batch-specific Certificate of Analysis (COA) and 16-section GHS Safety Data Sheet (SDS). Under the Vietnam Law on Chemicals No. 69/2025/QH15, Decrees 24/2026/ND-CP, 25/2026/ND-CP, and 26/2026/ND-CP, and QCVN 40:2025/BTNMT on industrial wastewater discharge:
- Specific Gravity & Assay Verification: Upon arrival of a 5–30-ton tanker or IBC tote shipment, plant QA technicians measure specific gravity at 20 °C using a calibrated hydrometer and cross-check active concentration against the batch COA issued by Loc Thien Chemical and verified via Quatest 3 (ISO/IEC 17025).
- Impurity & Heavy Metal Control: Trace heavy metals (Fe, Pb, As, Hg, Cd, Cr⁶⁺) and insoluble matter are strictly controlled to prevent catalyst poisoning in Fenton reactors, membrane fouling in RO/UF systems, or shade deviations in reactive textile dyeing.
- ZDHC MRSL v3.1 Level 1 Portfolio Boundary: For export-oriented textile and footwear FDI factories, Loc Thien Chemical maintains official ZDHC MRSL v3.1 Conformance Level 1 documentation for exactly 9 core products: four products certified by TUV SUD Product Service GmbH (
NaOH,H2O2,Na2SO4,Na2CO3) and five products verified via Conformance Summary Report (CSR) and Analytical Test Report by TUV Rheinland Vietnam (H2SO4,FeCl2,HCl,Javel/NaOCl,PAC 31%).
| Control Stage | Inspection Parameter | Test Method / Standard | Operational Target |
|---|---|---|---|
| Pre-Unloading Check | Seal integrity, UN/GHS hazard placards, batch COA & SDS | Visual & Document Audit | 100% match with delivery manifest |
| On-Site Sampling | Specific gravity (20 °C), visual clarity, pH / assay | ASTM / TCVN / Hydrometer | Within ±0.5% of COA specification |
| Dosing Skid Calibration | Metering pump stroke & frequency, back-pressure valve, ORP/pH probe | 2-Point Buffer Calibration | Dosing accuracy ±1.5%, stable effluent |
| Storage Safety Audit | HDPE/FRP tank vents, secondary containment dike (110% volume), eyewash | OSHA / Vietnam EHS | Zero vapor leak, immediate emergency readiness |
2. Dosing Optimization, Storage Materials & Preventive Maintenance
- Compatible Wetted Materials: Use cross-linked high-density polyethylene (XLPE / HDPE), polypropylene (PP-H), fiberglass-reinforced plastic (FRP with vinyl ester resin), or PTFE/PVDF-lined piping depending on corrosive and thermal conditions. Avoid unlined carbon steel or incompatible elastomers.
- Automated Dosing Control: Integrate diaphragm metering pumps with real-time pH, ORP (mV), turbidity, or conductivity sensors. Always perform a 5-beaker Jar Test whenever raw water COD, TSS, or alkalinity shifts by more than 15%.
- Secondary Containment & PPE: Storage tanks must sit inside an acid/alkali-resistant bund wall holding at least 110% of the largest tank volume. Operators handling unloading hoses must wear splash-proof chemical goggles, acid/alkali-resistant nitrile or neoprene gloves, face shields, and emergency respirators.
3. Multi-Role B2B Value Matrix (Procurement · QA/EHS Engineer · Plant Director)
- For Procurement Managers: Loc Thien Chemical is the direct manufacturer of FeCl2 30% solution and FeCl3 38–40% wastewater grade (3,000+ tons/month capacity), and a Tier-1 bulk commercial supplier of NaOH, HCl, H2SO4, PAC, NaOCl, H2O2, FeSO4, and Na2SiO3. Pricing is transparently structured around 5 technical cost drivers (active assay, packaging format, delivery distance from our 6 warehouses, order volume, and scheduled contract cadence) with a 15-minute technical quotation SLA.
- For Environmental & Process Engineers: Full technical support for Jar Test optimization, stoichiometry calculation, sludge minimization, and QCVN 40:2025/BTNMT compliance auditing.
- For FDI Plant Directors: Guaranteed supply continuity via 6 regional warehouses (Ba Ria - Vung Tau, Dong Nai, Binh Duong, Da Nang, Can Tho, Bac Ninh) and a dedicated 5–30-ton tanker fleet (4 hours in inner HCMC, 24–48 hours across Southern & Mekong Industrial Parks, 2–3 days in Northern & Central Vietnam).
4. Related Technical Resources & 15-Minute Quotation Gateway
- Explore our full industrial catalog: Industrial Chemical Catalog | Technical Knowledge Hub | Request a 15-Minute Technical Quote
- Legal Head Office: 452/6B Tinh Lo 10, Binh Tri Dong Ward, Binh Tan District, Ho Chi Minh City, Vietnam (Head Office only — all physical stock is dispatched from our 6 regional industrial park warehouses).
- 24/7 Technical Hotline: 0979 891 929 (Please contact hotline 0979 891 929 for detailed delivery procedures) | Official Email: [email protected]
Preventive Maintenance (PM) & Corrosion Inspection Schedule for Chemical Storage & Dosing Skids
To prevent unplanned downtime, flange weeping, or sensor drift in industrial water treatment and manufacturing plants, EHS and maintenance engineering teams should enforce the following preventive maintenance (PM) schedule:
| Equipment & Subsystem | Inspection Frequency | Technical Inspection Scope & Engineering Standard | Corrective Action Upon Deviation |
|---|---|---|---|
| Bulk Storage Tanks (HDPE / XLPE / FRP) | Monthly | Inspect PTFE/EPDM flange gaskets, sight-glass level gauges, scrubber breathers, and 110%-capacity containment dike | Depressurize line, re-torque bolts, and replace aged gaskets immediately |
| Diaphragm Metering Pumps & Piping | Bi-weekly | Calibrate volumetric flow rate using a graduated calibration cylinder (target accuracy ±2%); clean Y-strainers and check valves | Flush crystallized deposits from ball checks and bleed air locks |
| Online pH / ORP / Conductivity Probes | Weekly | Perform two-point buffer calibration (pH 4.00 / 7.00 / 10.01) and clean glass bulb fouling | Regenerate sluggish electrodes in dilute HCl solution or replace probe |
| ANSI Z358.1 Emergency Shower & Eyewash | Weekly | Activate flow for 30 seconds to verify pressure, tepid water clarity, and unobstructed access | Clear nozzle blockages and log inspection in plant EHS register |
Incoming Tanker & IBC Tote Quality Verification & Batch COA Audit Protocol
Every chemical shipment delivered to FDI factories in Vietnam must undergo a structured 4-stage receiving audit in compliance with the Vietnam Law on Chemicals (No. 69/2025/QH15) and ISO 9001 / ISO 14001 quality systems:
| Verification Stage | Mandatory Audit Items & Documentation | Test Instrument / Reference Standard | Acceptance Criteria & Release Rule |
|---|---|---|---|
| Stage 1: Seal & Manifest Audit | Verify numbered tamper-evident security seals, batch COA (inspected by QC Phan Cam Thuy, approved by Vo Thi Nhu Hoa), and 16-section GHS SDS | Visual & Document Cross-Check | Intact security seal and 100% batch number match with COA |
| Stage 2: Specific Gravity & Visual Check | Wear full chemical PPE to draw a composite sample; measure specific gravity (SG at 20 °C) and visual clarity | Calibrated Glass Hydrometer (ASTM / TCVN) | Measured SG within ±0.5% of batch COA specification |
| Stage 3: Active Assay & Impurity Titration | Lab verification of primary active concentration and restricted trace impurities (Fe, heavy metals, insolubles) | Acid-Base / Redox Titration / Quatest 3 Method | 100% compliance with technical specification & ZDHC limits |
| Stage 4: Controlled Unloading & Retention | Confirm receiving tank ullage, lock camlock couplings, and retain a sealed 500 mL reference sample for 90 days | Dual-Operator Sign-Off Protocol | Zero spill during transfer and complete traceability labeling |